Device parameters and interfaces
8.1.7.25 Module 24: Min./max. speed
Description
The min./max. speed function monitors the speed value and transfers the maximum and
minimum value to the PROFIBUS master. Recording can be controlled via module 22
"Speed measurement control". It is also possible to reset values to the initialization value via
module 22.
Parameters
None
Input data
Input data
a
Minimum speed for detected
Min. speed
period.
b
Maximum speed for detected
period.
Max. speed
Input data length: 8 byte
Output data
None
86
Description
addr.
Rel.
Data
Value range
type
unsign
0
0 ... 10,000,000
32
unsign
4
0 ... 10,000,000
32
BPS 34
Default
Unit
CR to
module
0
Scaled
22
0
Scaled
Leuze electronic