Device parameters and interfaces
8.1.7.7 Module 7: Switching input
Note!
Underlined in the CR column are the modules which must be activated in addition to the cur-
rent module.
Description
The module defines the mode of operation of the digital switching input.
Parameters
Parameter
a
The parameter defines the logic
of the applied signal. In case of
an inversion, an external HIGH
Inversion
level is interpreted as an internal
LOW level.
b
This parameter controls the
release of the switching input.
Mode
c
This parameter defines a
debounce time which is imple-
mented via software.
Debounce
time in
[ms]
d
The parameter influences the
timing during switch-on.
Start-up
delay in
[ms]
e
The parameter defines the mini-
mum pulse duration of the input
signal.
Pulse dura-
tion in [ms]
60
Description
addr.
Rel.
Data
Value range
type
unsign
0: No (active high)
0
8
1: Yes (active low)
unsign
0: Off
1
8
1: On
unsign
2
0 ... 255
8
unsign
3
0 ... 65,535
16
unsign
5
0 ... 65,535
16