Leuze electronic BPS 34 Operating Instructions Manual page 67

Bar code positioning system profibus dp
Hide thumbs Also See for BPS 34:
Table of Contents

Advertisement

Device parameters and interfaces
Note!
The standby function can only be activated while in "Measure" state. This function switches
off the motor and laser. It takes approx. 2seconds to switch the BPS 34 back on (valid mea-
surement values at the interface).
In "Idle" state, the motor continues to run. Only the laser is switched off. It takes
approx. 1second to switch the BPS 34 back on (valid measurement values at the interface).
If the start-stop event is to occur at the switching input, the "function" parameter must be
configured with the "start/stop measurement" parameter in module 7 "Switching input".
8.1.7.10 Module 10: Measurement value acquisition
Description
With this module, a working range on the bar code tape can be defined. The BPS 34 outputs
position values within these minimum and maximum limits. Outside of these limits, a position
value of zero is output.
Parameters
Parameter
a
Max.
Maximum permitted measure-
measure-
ment length
ment
length in
[mm]
b
Min.
Minimum permitted measure-
measure-
ment length
ment
length in
[mm]
Parameter length: 8 byte
Note!
The signal output can be used to indicate that the measured value is outside of the measure-
ment range. To enable this function, the "outside measurement range" or "inside measure-
ment range" parameter must be activated in module 8.
Hex coding of module 10 "Measurement value acquisition"
The value listed in the table shows the hex coding of the default settings.
66
Description
addr.
Rel.
Data
Value range
type
unsign
0
0 ... 2,147,483,647
32
unsign
4
0 ... 2,147,483,647
32
BPS 34
Default
Unit
module
10,000,000
mm
0
mm
Leuze electronic
CR to
8d
8d