Leuze electronic BPS 34 Operating Instructions Manual page 83

Bar code positioning system profibus dp
Hide thumbs Also See for BPS 34:
Table of Contents

Advertisement

Device parameters and interfaces
8.1.7.23 Module 22: Speed measurement control
Description
The control manages the timing of the speed measurement by starting or stopping the
measurement function. Control is performed depending on certain events such as the
switching input, time functions or PROFIBUS output bits. Using parameters, it determines
the events which influence the states.
Parameters
Parameter
Description
a
The start mode determines by
Speed
which event the speed mea-
measure-
surement is started.
ment start
mode
b
The stop mode determines
Speed
after which event the speed
measure-
measurement is stopped.
ment stop
mode
Parameter length: 2 byte
Hex coding of module 22 "Speed measurement control"
The value listed in the table shows the hex coding of the default settings.
18
82
Rel.
Data
addr.
type
unsign
0
8
unsign
1
8
00
00
BPS 34
Value range
0: Deactivated
1: After initialization
2: Following event:
Either by the switching input
or by a signal from the
PROFIBUS master
0: Deactivated
1: By errors
2: By a stop event:
Either by output bit 0.1 or by
the switching input function
Default
Unit
CR to
module
0
7g
0
7g
Leuze electronic