Leuze electronic BPS 34 Operating Instructions Manual page 66

Bar code positioning system profibus dp
Hide thumbs Also See for BPS 34:
Table of Contents

Advertisement

03
Input data
Input data
d
Signals the current state of the
Position
internal position control of the
control
BPS 34
state
Input data length: 1 byte
Note!
These input data signal the state of the BPS 34:
• Init: Base setting during initial startup of the BPS 34
• Idle: The BPS 34 is in idle state (scanning beam is off, but motor is running)
• Measure: The BPS 34 is in measurement state (data are output in module 1)
• Standby: The BPS 34 is in waiting state (laser off and motor off).
Output data
Output
data
e
Event starts position measure-
Start
ment
event
f
Event stops position measure-
ment
Stop event
g
Switches the BPS 34 to standby
BPS
operation
standby
Output data length: 1 byte
Leuze electronic
01
04
27 10
Description
addr.
Description
addr.
Device parameters and interfaces
Rel.
Data
Value range
type
0: Init
unsign
1: Idle
0
8
2: Measure
4: Standby
Rel.
Data
Value range
type
0.0
Bit
0 -> 1: Start
0.1
Bit
0 -> 1: Stop
0: BPS active
0.7
Bit
1: BPS in standby mode
BPS 34
Default
Unit
CR to
module
0
Default
Unit
CR to
module
0
7g
0
0
65

Advertisement

Table of Contents
loading

Table of Contents