Electrical Connection - Leuze electronic BPS 34 Operating Instructions Manual

Bar code positioning system profibus dp
Hide thumbs Also See for BPS 34:
Table of Contents

Advertisement

4.3

Electrical connection

The BPS 34 can be connected via the MS 34 103/MS 34 105 using M12 connectors. For the
locations of the individual device connections, please refer to the device detail shown in
Figure 4.3.
The corresponding mating connectors and ready-made cables are available as accessories
for all connections. For additional information, refer to Chapter 10 starting on Page 95.
Attention!
Connection of the device and cleaning must only be carried out by a qualified electrician.
If faults cannot be cleared, the device should be switched off and protected against acciden-
tal use.
Before connecting the device, be sure that the supply voltage agrees with the value printed
on the name plate.
The power supply unit for the generation of the supply voltage for the BPS 34 and the
respective connection units must have a secure electrical insulation through double insula-
tion and safety transformers according to EN 60742 (corresponds to IEC 60742).
Be sure that the protective conductor is connected correctly. Fault-free operation is only
guaranteed when the device is properly earthed.
Leuze electronic
BPS 34