8.1.7.5 Module 5: Offset value
Note!
Underlined in the CR column are the modules which must be activated in addition to the cur-
rent module.
Description
This module adds an offset value to the tape value.
Parameters
Parameter
a
Offset
Offset value added to tape value
value in
[mm]
Parameter length: 4 byte
Note!
If module 3 "Static preset" or module 4 "Dynamic preset" is activated and, as a result, a new
value assigned to the tape value, the offset function no longer affects the position value. The
offset is not reactivated until the preset function (static and dynamic) is canceled. The offset
value is entered in mm. When entering the offset value, the scaling in module 6 must be
taken into account.
Hex coding of module 5 "Offset value"
The value listed in the table shows the hex coding of the default settings.
09
Input data
None
Output data
None
Leuze electronic
Description
addr.
00 00 00 00
Device parameters and interfaces
Rel.
Data
Value range
type
0
sign32 -10,000,000 ... 10,000,000
BPS 34
Default
Unit
CR to
module
0
mm
1