Mounting
Mounting example BPS 34
BT 56
mounting device
Figure 7.3:Mounting example BPS 34
Note!
During mounting, the following angles of inclination must be taken into account in the vertical
axis:
10° for a tape height of 47mm,
7° for a tape height of 30mm and
5° for a tape height of 25mm;
the working range of the reading field curve must also be taken into account.
Attention!
For the position calculation, the scanning beam of the BPS 34 must be incident on the bar
code tape without interruption. Ensure that the scanning beam is always incident on the bar
code tape when the system is moving.
40
BPS 34
BPS 34
Modular connector hood
MS 34 103 or
MS 34 105