Advertisement

5
MS 34 ... / MSD 1 101 connection units
5.1

MS 34 103 and MS 34 105 modular connector hoods

A modular connector hood of type MS 34 103 or MS 34 105 is part of every BPS 34. The
two connector hoods are used to connect the BPS 34 to the PROFIBUS. For this, they
feature one DP IN and one DP OUT connection each, as well as switches for address
setting.
If only the connection to the PROFIBUS is intended, type MS 34 103 is sufficient.
If, in addition, a switching input/output or modular service display are to be connected, an
MS 34 105 is required. Although switching input and output are available on the PWR IN
voltage supply connector, the switching input of the MS 34 105 has the advantage that a
standard sensor connector can be used.
5.1.1

General information

The modular connector hoods with integrated connectors are necessary accessories for
connecting a BPS 34 in a PROFIBUS system. On the MS 34 10x, the PROFIBUS is
connected, the PROFIBUS address set and the BPS 34 supplied with voltage.

MS 34 103

The MS 34 103 offers the following interfaces:
• PROFIBUS incoming DP IN
• PROFIBUS outgoing DP OUT
• Voltage supply PWR IN with switching input and switching output
MS 34 105
In addition to the MS 34 103, the MS 34 105 offers the following interfaces:
• For the MSD modular service display
• M12 connection for switching input and switching output SW IN/OUT
5.1.2

Technical data of the connection units

Mechanical data
Degree of protection
Weight
Dimensions (H x W x D)
Housing
1)
With M12 connectors/caps screwed into place
Leuze electronic
MS 34 ... / MSD 1 101 connection units
1)
IP 65
160g
38 x 90 x 39 mm
Diecast zinc
BPS 34
23