Leuze electronic BPS 34 Operating Instructions Manual page 64

Bar code positioning system profibus dp
Hide thumbs Also See for BPS 34:
Table of Contents

Advertisement

e
The parameter specifies the
events which reset the switching
output:
- speed valid
- speed not valid
- position limit value 1 reached
- position limit value 1 not
reached
- outside measurement range
Switch-off
- within measurement range
function
- position limit value 2 reached
[AF]
- position limit value 2 not
reached
- erroneous measurement
- successful measurement
- PROFIBUS pos. edge
- PROFIBUS neg. edge
- speed limit value reached
- speed limit value not reached
Parameter length: 8 byte
Note!
The events of the switch-on function and switch-off function are both linked to one another
with a logical OR.
Hex coding of module 8 "Switching output"
The value listed in the table shows the hex coding of the default settings.
02
Input data
None
Output data
Output
data
f
This bit can be used to operate
Switching
the switching output if the "PRO-
output
FIBUS edge" function is config-
PROFIBUS
ured.
edge
Output data length: 1 byte
Leuze electronic
00
00
01 90
Description
addr.
Device parameters and interfaces
6.0
6.1
6.2
6.3
6.4
For each
6.5
Bits
0: Not active
6.6
1: Active
6.7
7.2
7.3
7.4
7.5
7.6
7.7
04 00
08 00
Rel.
Data
Value range
type
0 -> 1: Positive edge
0.0
Bit
1 -> 0: Negative edge
BPS 34
0
22
0
22
0
14 + 16
0
14 + 16
0
10
0
10
0
15 + 17
0
15 + 17
0
1 + 9
1
1 + 9
0
8
0
8
0
25
0
25
Default
Unit
CR to
module
0
63