Device parameters and interfaces
8.1.7.13 Module 12: Status
Note!
Underlined in the CR column are the modules which must be activated in addition to the cur-
rent module.
Description
This module supplies various BPS 34 status information to the PROFIBUS master.
Parameters
None
Input data
Input data
a
Indicates that no valid integration
value could be determined (mea-
Measure-
surement value preparation mod-
ment error
ule).
b
Indicates that the measurement
range has been exceeded (mea-
Range sta-
surement value acquisition mod-
tus
ule)
c
Indicates a position value output
with active static preset or
Preset
dynamic preset (Preset module)
active
d
Toggle bit, changes during the
teach event for the static and
Preset
dynamic preset value (Preset
teach
module)
e
Position
Indicates that limit value 1 has
limit value
been exceeded (Measurement
status 1
value monitoring module).
(static or
dynamic)
f
Position
Indicates that limit value 2 has
limit value
been exceeded (Measurement
status 2
value monitoring module).
(static or
dynamic)
g
Signals the standby status (Con-
Standby
trol module)
status
Input data length: 1 byte
Output data
None
70
Description
addr.
Rel.
Data
Value range
type
0: OK
0.0
Bit
1: Error
0: OK, within measure-
ment range
0.1
Bit
1: Measurement range
exceeded
0: No preset active
0.2
Bit
1: Preset active
0.3
Bit
0.1: Dyn. preset teach
0: No limit value violation
0.4
Bit
1: Value greater than limit
0: No limit value violation
0.5
Bit
1: Value greater than limit
0: BPS active
0.7
Bit
1: BPS in standby mode
BPS 34
Default
Unit
CR to
module
0
0
10
3a
0
4c
3a
0
4c
14d
0
16d
15d
0
17d
0
9d
Leuze electronic