Repair Kit - Leuze electronic BPS 34 Operating Instructions Manual

Bar code positioning system profibus dp
Hide thumbs Also See for BPS 34:
Table of Contents

Advertisement

Bar code tape
Note!
When affixing the BCB in a system in which the end of one BCB meets the start of another
BCB (position value X with position value 0), ensure that position labels 0 - 20 are not used.
This means that position label 24 must be the first label used on the continuing bar code
tape.
Note!
If only the "MVS" label is read within the scanning beam, the scanning beam must not be
interrupted during the read operation until the scanner can again read a complete position
label.
If only the "MVS" label is located in the scanning beam, the voltage on the BPS 34 must not
be switched off. Otherwise the BPS 34 will return a position value of zero when the voltage
is switched back on.
Moreover, the scanner must not be configured while in this position. Otherwise, a value of
zero is output as long as no position label is present in the scanning beam due to the fact
that the scanning beam is switched off during configuration.
6.5

Repair kit

Note!
If the bar code tape was damaged, e.g. by falling parts, a repair kit can be downloaded from
the Internet (www.leuze.com).
In these files you will find all code information for a tape with the length of 500m within the
range of 0 ... 9999.96m. 1m of bar code tape is provided on each A4 sheet. Each meter is
divided into 5 lines of 20cm, each with 5 code segments of information covering lengths
of 4cm each.
Procedure when replacing the defective area:
1.
Determine the coding of the defective area.
2.
Print out the area determined to be defective
3.
Affix the printed area over the defective location
36