Note!
Some controls make available a so-called "universal module". This module must not be acti-
vated for the laser.
Attention!
The BPS 34 does not permanently store parameters changed via the PROFIBUS. Following
Power off/on, the currently configured parameters are downloaded from the PROFIBUS
manager. If no PROFIBUS manager is available following Power off/on, the BPS 34 acti-
vates its stored default settings.
8.1.5

Structure of the GSD modules

In the current version, a total of 27 modules are available for use. The modules may be
included into the project according to requirements and application.
The modules fall into the following categories:
• Parameter module for the configuration of the BPS 34.
• Status or control modules that influence the input/output data.
• Modules that may include both parameters and control or status information.
Note!
All input and output modules described in this documentation are described from the
viewpoint of the control:
Inputs (I) described are inputs of the control.
Outputs (O) described are outputs of the control.
Parameters (P) described are parameters of the GSD file in the control.
Note!
At least one module must be activated to permit operation of the device at the PROFIBUS
DP.
Note!
Under some circumstances, not all 27 modules can be activated simultaneously in the con-
figuration tool. Otherwise, the available memory for a participant may be exceeded. The
maximum available memory for a device is control dependent.
Leuze electronic
Device parameters and interfaces
BPS 34
47