Device parameters and interfaces
8.1.7.6 Module 6: Scaling
Note!
Underlined in the CR column are the modules which must be activated in addition to the cur-
rent module.
Description
The scaling function is used to convert the tape values to any unit of measurement. To do
this, the tape value is multiplied by the scaling factor.
Parameters
Parameter
a
Scaling factor used to convert the
Scaling
position values
factor in
[‰]
Parameter length: 2 byte
Note!
When entering offset values in module 5, it must be ensured that the scaling factor is taken
into account.
Affected by this module are:
• Offset value (module 5)
• Static position limit values 1 and 2 (modules 14 and 15)
• Hysteresis of static position limit values 1 and 2 (modules 14 and 15)
• Dynamic position limit values 1 and 2 (modules 16 and 17)
• Hysteresis of dynamic position limit values 1 and 2 (modules 16 and 17)
The static preset or dynamic preset modules (module 3 or module 4) are not affected by the
scaling.
58
Description
addr.
Rel.
Data
Value range
type
unsign
0
0 ... 65,535
16
BPS 34
Default
Unit
CR to
module
Per thou-
1,000
1
sand