Connecting the PROFIBUS
The PROFIBUS is connected via DP IN or, in the case of a continuing network, via DP OUT.
If DP OUT is not used, the PROFIBUS must be terminated at this point with an M12 termi-
nator plug (see chapter 10.4 "Accessories - Termination").
DP OUT
VCC 1
Socket
(B-coded)
Figure 3.3:BPS 34 with MS 34 103/MS 34 105 – DP IN and DP OUT connections
Setting the PROFIBUS address
The PROFIBUS address must be set in the MS 34 10x connector plug hood. The correct
address setting on the PROFIBUS network is indicated by the green LED on the MS 34 10x.
Figure 3.4:View of the inside of the MS 34
Leuze electronic
Socket
(A-coded)
MSD
VIN
2
/INT
3
/SERV
1
7
GND
6
SDA
A (N)
2
GND
3
4
PE
B (P)
Slide switch for the hundreds (marked with 10
Rotary switch for the tens (marked with 10
Rotary switch for the single digits (marked with 10
Fast commissioning steps at a glance
TXD
RXD
4
VOUT
5
SCL
DP IN
A (N)
2
GND 3
1
4
PE
B (P)
Plug
(B-coded)
Connection plug to the BPS 34
BPS 34
Socket
(A-coded)
SW IN/OUT
SWOUT
2
GND
1
3
4
PE
PWR IN
SWIN
3
VCC
GND
PE
2
)
1
)
0
)
Position of the slide
switches:
Top
address
100 - 126
Bottom address
1 - 99
SWOUT
2
VIN
1
4
SWIN
Plug
(A-coded)
11