WIRELESS CONNECTIVITY & SENSORS
User manual Proteus-III
Please refer to chapter 14 on how to use the bootloader for a firmware update.
Please note that you can only exit the bootloader mode by performing a hard-
ware reset using the respective pin.
The bootloader mode will also be enabled if the firmware image is marked "in-
valid" or if the BOOT pin logic level (set by the host) is set to start the bootloader
during start-up of the module.
Format:
Response ( CMD_BOOTLOADER_CNF ):
Start signal
0x02
Status:
0x00: Request received, will start bootloader now
0x01: Operation failed
0xFF: Operation not permitted
Order code 2611011024000
Version 1.8 , July 2022
Start signal
Command
0x02
0x1F
Command | 0x40
0x5F
Length
CS
0x00 0x00
0x1D
Length
Status
0x01 0x00
1 Byte
www.we-online.com/wcs
CS
1 Byte
89