Example 1; Example 2 - We PROTEUS-III User Manual

Hide thumbs Also See for PROTEUS-III:
Table of Contents

Advertisement

WIRELESS CONNECTIVITY & SENSORS
User manual Proteus-III
of the central are used for connection setup. If both modules have different connection
interval settings the peripheral requests the central to accept the peripheral's settings af-
ter 5s. The central accepts these settings, and thus the peripheral's connection interval
is used.
If now another Bluetooth
Proteus-III module (peripheral) and the connection interval settings do not coincide, the
Proteus-III requests the smart phone to accept its settings after 5s. If the cell phone
does not accept the settings, it will be requested a further 3 times with a delay of 10s.
If the peripheral's settings request have been rejected in all cases the connection will be
shut down. If the smart phone itself requests to update the connection interval of the
Proteus-III, the module accepts the request. Reversely, if a Proteus-III (central) connects
to another Bluetooth
coincide, the Proteus-III accepts all requests of the peripheral to update the connection
parameter settings.
• The connection supervision timeout defines the time after which an already established
connection is considered as lost, when no further communication has occurred.
Please ensure that all members (Proteus-III, cell phones and other
Bluetooth
ters to avoid connection problems and changes of the connection interval dur-
ing an opened connection.
Please check the minimum connection interval that is supported by iOS. Former
iOS devices do not support connection intervals shorter than 30ms!

8.16.1. Example 1

Set the connection timing parameter to 0x00 using CMD_SET_REQ with settings index 8.
Start signal
0x02
Response CMD_SET_CNF : Successfully modified the setting.
Start signal
0x02

8.16.2. Example 2

Request the connection timing parameter of the module using CMD_GET_REQ with settings index
8
Order code 2611011024000
Version 1.8 , July 2022
®
LE device (e.g. a smart phone) connects as central to a
®
LE device (peripheral) and the connection interval settings do not
®
LE devices) of a network use the same connection timing parame-
Command
Length
0x11
0x02 0x00
Command | 0x40
0x51
Settings index
Parameter
0x08
0x00
Length
Status
0x01 0x00
0x00
www.we-online.com/wcs
CS
0x19
CS
0x52
145

Advertisement

Table of Contents
loading

This manual is also suitable for:

Proteus-iii-spi26110110240102611011024000

Table of Contents