WIRELESS CONNECTIVITY & SENSORS
User manual Proteus-III
8.25. DIS_ManufacturerName: Configure the manufacturer name
Settings
Designation
index
DIS_ManufacturerName
20
The user setting DIS_ManufacturerName specifies the content of the manufacturer name field
of the Device Information Service. The permissible characters are in the range of 0x20 - 0x7E
which are special characters (see ASCII table), alphabetic characters (a-z and A-Z), numbers
(0-9) and whitespace.
To add the content of the DIS_ManufacturerName to the DIS profile, please set
the corresponding Bit in the DIS_Flags .

8.25.1. Example 1

Set the manufacturer name to "Manufacturer1" using CMD_SET_REQ with settings index 20
Start signal
Command
0x02
0x11
Response CMD_SET_CNF : Successfully modified the setting.
Start signal
0x02

8.25.2. Example 2

Request the manufacturer name of the DIS profile using CMD_GET_REQ :
Start signal
0x02
Response CMD_GET_CNF : Successfully read out the value "Default".
Order code 2611011024000
Version 1.8 , July 2022
Permissible
values
See
description
Length
Settings index
0x0E 0x00
0x14
Command | 0x40
0x51
Command
Length
0x10
0x01 0x00
Permissions
Default value
"Default"
read/write
Parameter
0x4D 0x61 0x6E 0x75 0x66
0x61 0x63 0x74 0x75 0x72
0x65 0x72 0x31
Length
Status
0x01 0x00
0x00
Settings index
0x14
www.we-online.com/wcs
Number
of
Bytes
1-64
CS
0x0F
CS
0x52
CS
0x07