We PROTEUS-III User Manual page 35

Hide thumbs Also See for PROTEUS-III:
Table of Contents

Advertisement

WIRELESS CONNECTIVITY & SENSORS
User manual Proteus-III
4. Once the connection is active, data can be sent in each direction. Let us send a string
"ABCD" from module B to module A.
The RSSI values will be different in your tests.
Info
Request CMD_DATA_REQ : Send "ABCD" to
module A
Response CMD_DATA_CNF : Request received,
send data now
Indication CMD_DATA_IND : Received string
"ABCD" from FS_BTMAC
0x18 0x00
with RSSI of 0xCA (-54 dBm)
Response CMD_TXCOMPLETE_RSP : Data
transmitted successfully
5. Reply with "EFGH" to module B.
Info
Request CMD_DATA_REQ : Send "EFGH" to
module B
Response CMD_DATA_CNF : Request received,
send data now
Indication CMD_DATA_IND : Received string
"EFGH" from FS_BTMAC
0x18 0x00
with RSSI of 0xC1 (-63dBm)
Response CMD_TXCOMPLETE_RSP : Data
transmitted successfully
6. Now module A closes the Bluetooth
nect indication message.
Info
Request CMD_DISCONNECT_REQ : Disconnect
Response CMD_DISCONNECT_CNF : Request
received, disconnect now
Indication CMD_DISCONNECT_IND : Connection
closed
Indication CMD_DISCONNECT_IND : Connection
closed
Order code 2611011024000
Version 1.8 , July 2022
0x11 0x00 0x00 0xDA
0x55 0x00 0x00 0xDA
®
LE connection, so both modules will get a discon-
Module A
02 84 0B 00
11 00
00 DA 18 00
CA
41
42 43 44
90
Module A
02 04 04 00
45 46 47
48
0E
02 44 01 00 00 47
02 C4 01 00 00 C7
Module A
02 07 00 00 05
02 47 01 00 00 44
02 87 01 00 16 92
www.we-online.com/wcs
Module B
02 04 04 00
41 42 43
44
06
02 44 01 00 00 47
02 C4 01 00 00 C7
Module B
02 84 0B 00
55 00
00 DA 18 00
C1
45
46 47 48
D7
Module B
02 87 01 00 13 97
33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Proteus-iii-spi26110110240102611011024000

Table of Contents