Please note that due to the HF-activity of the chip, single Bytes on the UART
can get lost, when using a very fast UART data rate. To avoid loosing single
bytes, please enable the UART flow control.

8.23.1. Example 1

Set the baud rate index to 0x1F (921600 Baud with flow control and parity none) using CMD_
SET_REQ with settings index 11
Start signal
0x02
Response CMD_SET_CNF : Successfully modified the setting.
Start signal
0x02

8.23.2. Example 2

Request the baud rate index of the module using CMD_GET_REQ with settings index 11
Start signal
0x02
Response CMD_GET_CNF : Successfully read out the value 0x16, which equals 115200 Baud
without flow control and parity none.
Start signal
0x02
Order code 2611011024000
Version 1.8 , July 2022
Command
Length
0x11
0x02 0x00
Command | 0x40
0x51
Command
Length
0x10
0x01 0x00
Command | 0x40
0x50
0x02 0x00
Settings index
Parameter
0x0B
Length
Status
0x01 0x00
0x00
Settings index
0x0B
Length
Status
Parameter
0x00
CS
0x1F
0x05
CS
0x52
CS
0x18
CS
0x16
0x46