WIRELESS CONNECTIVITY & SENSORS
User manual Proteus-III
Indication CMD_SECURITY_IND , status
(encrypted link, pairing, no bonding), with
FS_BTMAC
0x55 0x00 0x00 0xDA 0x18 0x00
Info
Indication CMD_CHANNELOPEN_RSP : Channel
opened successfully to module with FS_BTMAC
0x11 0x00 0x00 0xDA 0x18 0x00
payload size of
0xF3
Indication CMD_CHANNELOPEN_RSP : Channel
opened successfully to module with FS_BTMAC
0x55 0x00 0x00 0xDA 0x18 0x00
payload size of
0xF3
5. Once the connection is active, data can be sent in each direction. Let us send a string
"ABCD" from module B to module A.
The RSSI values will be different in your tests.
Info
Request CMD_DATA_REQ : Send "ABCD" to
module A
Response CMD_DATA_CNF : Request received,
send data now
Indication CMD_DATA_IND : Received string
"ABCD" from FS_BTMAC
0x18 0x00
with RSSI of 0xCA (-54 dBm)
Response CMD_TXCOMPLETE_RSP : Data
transmitted successfully
6. Reply with "EFGH" to module B.
Info
Request CMD_DATA_REQ : Send "EFGH" to
module B
Response CMD_DATA_CNF : Request received,
send data now
Order code 2611011024000
Version 1.8 , July 2022
0x02
and maximum
(243 Bytes) per packet
and maximum
(243 Bytes) per packet
0x11 0x00 0x00 0xDA
Module A
02 C6 08 00 00
11 00
00 DA 18 00
F3
EC
Module A
02 84 0B 00
11 00
00 DA 18 00
CA
41
42 43 44
90
Module A
02 04 04 00
45 46 47
48
0E
02 44 01 00 00 47
www.we-online.com/wcs
02 88 07 00
02
55 00
00 DA 18 00
18
Module B
02 C6 08 00 00
55 00
00 DA 18 00
F3
A8
Module B
02 04 04 00
41 42 43
44
06
02 44 01 00 00 47
02 C4 01 00 00 C7
Module B
40