7.2.15. CMD_ALLOWUNBONDEDCONNECTIONS_REQ

In case the SECFLAGS_BONDEDCONNECTIONSONLY_ENABLE bit has been set in the RF_SecFlags
user setting, this command temporarily allows the connection setup of unbonded devices until
the radio module is reset.
Format:
Response ( CMD_ALLOWUNBONDEDCONNECTIONS_CNF ):
Start signal
0x02
Status:
0x00: Request successfully processed
0x01: Operation failed
0xFF: Operation not permitted
Order code 2611011024000
Version 1.8 , July 2022
Start signal
Command
0x02
0x2D
Command | 0x40
0x6D
Length
CS
0x00 0x00
0x2F
Length
Status
CS
2 Bytes
1 Byte
1 Byte