WIRELESS CONNECTIVITY & SENSORS
User manual Proteus-III
Start signal
Command
0x02
Response ( CMD_SET_CNF ):
Start signal
0x02
Status:
0x00: Request received, settings set successfully
0x01: Operation failed due to invalid parameter
0x04: Serious error, when writing flash. Try to factory reset or re-flash the device
0x05: Supply voltage too low. Please apply correct supply voltage, reset and retry.
0xFF: Operation not permitted

7.4.1.1. Example 1

Setting the advertising time RF_AdvertisingTimeout to 180 seconds.
Start signal
0x02
Response:
Start signal
0x02
Setting was set successfully.

7.4.1.2. Example 2

Setting the static pass key RF_StaticPasskey to "123456".
Start signal
Command
0x02
Response:
Order code 2611011024000
Version 1.8 , July 2022
Length
Settings index
0x11
2 Bytes
Command | 0x40
0x51
Command
Length
0x11
0x03 0x00
Command | 0x40
0x51
Length
0x11
0x07 0x00
Parameter
1 Byte
(Length - 1) Bytes
Length
Status
0x01 0x00
1 Byte
Settings index
Parameter
0x07
0xB4 0x00
Length
Status
0x01 0x00
0x00
Settings index
Parameter
0x31 0x32 0x33
0x12
0x34 0x35 0x36
CS
1 Byte
CS
1 Byte
CS
0xA3
CS
0x52
CS
0x01