Watch Timer Operations; Watch Timer Operation; Interval Timer Operation - NEC mPD780852 Series Preliminary User's Manual

8-bit single-chip microcontrollers
Table of Contents

Advertisement

9.4 Watch Timer Operations

9.4.1 Watch timer operation

When the 8.38-MHz main system clock is used, the timer operates as a watch timer with a 0.25-second interval.
The watch timer generates interrupt requests at a constant time interval.
When bit 0 (WTM0) and bit 1 (WTM1) of the watch timer mode control register (WTM) are set to 1, the count
operation starts. When set to 0, the 5-bit counter is cleared and the count operation stops.
For simultaneous operation of the interval timer, zero-second start can be set only for the watch timer by setting
WTM1 to 0. However, since the 9-bit prescaler is not cleared the first overflow of the watch timer (INTWT) after zero-
second start may include an error of up to 2

9.4.2 Interval timer operation

The watch timer operates as interval timer which generates interrupt request repeatedly at an interval of the preset
count value.
The interval time can be selected with bits 4 to 6 (WTM4 to WTM6) of the watch timer mode control register (WTM).
WTM6
WTM5
0
0
0
0
0
1
0
1
1
0
1
0
Other than above
Remark f
: Watch timer clock frequency
W
140
CHAPTER 9 WATCH TIMER
× 1/f
9
.
W
Table 9-3. Interval Timer Interval Time
WTM4
Interval Time
× 1/f
4
0
2
W
× 1/f
5
1
2
W
× 1/f
6
0
2
W
× 1/f
7
1
2
W
× 1/f
8
0
2
W
× 1/f
9
1
2
W
Setting prohibited
Preliminary User's Manual U14581EJ3V0UM00
When Operated at
When Operated at
f
= 65.4 kHz
f
W
W
244 µ s
3.91 ms
489 µ s
7.81 ms
978 µ s
15.6 ms
1.96 ms
31.3 ms
3.91 ms
62.5 ms
7.82 ms
125 ms