Self-Tests 13xx: A11 Analog/Pulse Modulation Generator Self-Test Errors

Figure 1-11
Before proceeding to the reported self-test error code, check the voltages in Table1-30. If any of
these voltages are out of specification troubleshoot the supply problem first.
Table 1-30
Supply
Voltage
(Vdc)
+15
-15
+5.2
-5.2
+5.2 Digital high
+3.4 Digital Low
1300 Power Supply
1. Replace the A7 Reference.
Connector
Minimum
Pins
Value
(Vdc)
P132-28
+14.55
P132-3
-14.55
P132-2, 27
+5.04
P132-1, 26
-5.1
P131-64, 65,
+5.04
129, 130
P131-60, 61,
+3.29
62, 63, 125,
126, 127, 128
Troubleshooting Assembly Level Problems
Maximum
Origin
Value
(Vdc)
+15.45
Main Supply
-15.45
Main Supply
+5.37
Main Supply
-5.3
YIG Driver
+5.36
Main Supply
+3.5
Main Supply