Ment 14.3 Rem Setting-Out Measurement - Sokkia 130R Series Operator's Manual

Reflectorless total station
Table of Contents

Advertisement

14.3
REM Setting-out Measurement
To find a point where a target cannot be directly installed, perform REM setting-
out measurement.
"11.5 REM Measurement"
PROCEDURE
1. Install a target directly below or
directly above the point to be
found, then use a measuring tape
etc. to measure the target height
(height from the surveying point to
the target).
2. Press [S-O] in the Meas mode
screen to display <S-O>.
3. Enter the instrument station data.
"12.1 Entering Instrument
Station Data, PROCEDURE
Reading in Registered
Coordinate Data".
4. Select "S-O data" and press [ S-
O] until <S-O Ht.> is displayed.
5. Input height from the surveying
point to the position to be set out
in "SO dist".
6. After inputting the data, press
[OK].
14. SETTING-OUT MEASUREMENT
H t .
H e i g h t :
S-O
3 . 3 0 0
m
OK
63