14. SETTING-OUT MEASUREMENT
2. Enter the instrument station data.
"12.1 Entering Instrument
Station Data PROCEDURE
Reading in Registered
Coordinate Data".
3. Set the azimuth angle of the
backsight point.
"12.2 Azimuth Angle Setting"
steps 2 to 6
4. Select "S-O data" and press [ S-
O] until <S-O Coord> is displayed.
5. Enter the coordinates of the
setting-out point.
• When [READ] is pressed,
registered coordinates can be
recalled and used as setting-out
coordinates.
"12.1 Entering Instrument
Station Data, PROCEDURE
Reading in Registered
Coordinate Data"
6. Press [OK] to set the setting-out
data.
7. Press [OBS] to begin coordinate
setting-out measurement.
Move the prism to find the point to
be set out.
"14.1 Distance Setting-out
Measurement" steps 9 to 10
: Move the prism upward.
: Move the prism downward.
8. Press {ESCAPE} to return to <S-
O>. When [READ] was used in
step 5, the list of registered
coordinates is restored. Continue
setting-out measurement.
62
C o o r d
S-O
READ
O B S
P 1
OK
R E C