17. SETTING-OUT MEASUREMENT
6. Press {ESC} to return to <Key in coord>. Set the
next setting out point to continue setting out
measurement.
17.4

REM Setting-out Measurement

To find a point where a target cannot be directly installed, perform REM setting-out measurement.
"14.5 REM Measurement"
PROCEDURE
1. Install a target directly below or directly above the
point to be found. Then use a measuring tape etc.
to measure the target height (height from the
surveying point to the target).
2. Select "Station setup" in <Setting out> to display
<Height setting>. If necessary, enter data for
Backsight setup.
"17.2 Distance Setting-out Measurement"
steps 2 to 3
3. Select "SO data setting" In <Setting out> to
display <SO data setting>. Press [/Shvr] until the
distance input mode is "Ht.". Input height from the
surveying point to the position to be set out in
"SO.Height". If necessary, input the angle to the
point to be set out.
4. Enter values and press [OK] in step 3 to display
the screen at right.
Press [H.ROTA] to automatically rotate the SRX
toward the horizontal angle set in step 3 and set
the angle to the setting out point to 0°.
98