Rem Setting-Out Measurement - Sokkia iM-50 Series Operator's Manual

Sokkia
Table of Contents

Advertisement

10.Press {ESC} to return to <S-O>.
• When [LOAD] was used in step 4, the list of registered
coordinates is restored. Continue setting-out
measurement.
• [REC]: records measurement results
Recording method: "28. RECORDING DATA - TOPO
MENU -"

15.3 REM Setting-out Measurement

To find a point where a target cannot be directly installed, perform REM setting-out measurement.
 "12.6 REM Measurement"
PROCEDURE
1. Install a target directly below or directly above the point to
be found, then use a measuring tape etc. to measure the
target height (height from the survey point to the target).
2. Press [S-O] in the OBS mode screen to display <S-O>.
3. Enter the instrument station data.
"13.1 Entering Instrument Station Data and Azimuth
Angle "
4. Select "S-O data" and press [DISP] until <S-O Ht.> is
displayed.
5. Input height from the survey point to the position to be set
out in "SO dist".
6. After inputting the data, press [OK].
• The tilt screen is displayed if the instrument is out of level.
Level the instrument.
"7.2 Levelling"
7. Press [REM] to begin REM setting-out measurement.
Move the telescope to find the point to be set out.
"15.2 Distance Setting-out Measurement" steps 9 to 10
: Move the telescope near the zenith.
: Move the telescope near the nadir.
8. When measurement is complete, press [STOP]. Pressing
[ESC] returns to the screen in step 5.
15. SETTING-OUT MEASUREMENT
H t .
H e i g h t :
H R
Cutl
SD
ZA
HA-R
MEAS
64
3 . 3 0 0
m
1 . 0 0 0 m
OK
DISP
DISP
REM

Advertisement

Table of Contents