• When using the Laser-pointer function, be sure to turn OFF the output laser
after distance measurement is completed. Even if distance measurement is
canceled, the Laser-pointer function is still operating and the laser beam
continues to be emitted. (After turning ON the Laser-pointer, the laser beam is
emitted for 5 minutes, and then automatically switches OFF. But in the Status
screen and when target symbol (ex.
mode, the laser beam is not automatically turned off. )
• Only those who have been received training as per the following items shall use
this product. (SET 1130R3/2130R3/3130R3/4130R3 only)
• Read the Operator's manual for usage procedures for this product.
• Hazardous protection procedures (read this chapter).
• Requisite protective gear (read this chapter).
• Accident reporting procedures (stipulate procedures beforehand for
transporting the injured and contacting physicians in case there are laser
induced injuries).
• Persons working within the range of the laser beam are advised to wear eye
protection for Helium Neon radiation. Recommended safety glasses from
Yamamoto Optics Co., Ltd. (SET 1130R3/2130R3/3130R3/4130R3 only)
Full Absorption type YL-331 (for He-Ne laser radiation) or
type YL-331M (for visible semiconductor laser radiation)
• Areas in which the lasers are used should be posted with laser warning notices.
(SET 1130R3/2130R3/3130R3/4130R3 only)
3. LASER SAFETY INFORMATION