25. CHANGING THE SETTINGS
EDM ALC
Set the light receiving status of the EDM. While carrying out continuous
measurement, set this item according to the measurement conditions.
• When EDM ALC is set to "Free," the amount of light received is adjusted by
the instrument's EDM ALC. Set to "Free" when the target is moved during
measurement or different targets are used.
• When "Hold" is set, the amount of light received remains fixed until
continuous measurement is completed.
• If an obstacle intermittently obstructs the light beam during continuous
measurement and the "Signal off" error occurs, each time the obstruction
occurs it takes some time for the amount of light received to be adjusted
and the measurement value displayed. Set to "Hold" when the light beam
used for measurement is stable but is frequently obstructed by obstacles
such as people, cars, or tree branches etc.
• The EDM ALC setting will automatically be switched to "Free" when the
distance measurement mode is set to "Tracking" (target is moved during
distance measurement).
Communication Setup
Select "Comms setup" in Config mode
Items set and options (*: Factory setting)
Baud rate
Data bits
Parity
Stop bit
Check sum
Xon/Xoff
Output format and command operations: "Interfacing with the SOKKIA SDR
Electronic Field Book" and "Command Operations" manuals.
124
d
1200bps*, 2400bps, 4800bps, 9600bps,
19200bps, 38400bps
8bit*, 7bit
Not set*, Odd, Even
1bit*, 2bit
Yes, No*
Yes*, No