20. RECORDING DATA - RECORD MENU -
3. Set the following data items.
(1) Instrument station coordinates
(2) Point number
(3) Instrument height
(4) Codes
(5) Operator
(6) Weather
(7) Wind
(8) Temperature
(9) Air pressure
(10)Atmospheric correction factor
• When inputting code, press [↑] /
[↓] to use the registered codes.
Align the cursor where you want
to input the registred code.
• To set the atmospheric
correction factor to 0ppm, press
[0ppm]. The temperature and air
pressure are set to the default
setting.
4. Check the input data, then press
[OK].
5. Press {ESCAPE} to quit
measurement and restore <REC>.
• SET automatically increments the last input number by 1.
• Maximum point number size: 14 (alphanumeric)
• Input range of instrument height: -9999.999 to 9999.999 (m)
• Maximum code/operator size: 16 (alphanumeric)
• The Date and Time cannot be changed.
Changing the Date and Time: "25.2 Configuration -Config Mode- Setting
Date and Time"
• Weather selection: Fine, Cloudy, Light rain, Rain, Snow
• Wind selection: Calm, Gentle, Light, Strong, Very strong
• Temperature range: -30 to 60 (°C) (in 1°C step)/-22 to 140 (°F) (in 1°F step)
• Air pressure range: 500 to 1400 (hPa) (in 1 hPa step)/375 to 1050 (mmHg)
(in 1mmHg step)/14.8 to 41.3 (inch Hg) (in 0.1 inch Hg step)
• Atmospheric correction factor range (ppm): -499 to 499
90