Technical specifications

12.2 General technical specifications

12.2
General technical specifications
Table 12-1
General technical specifications
Electrical data
Line frequency
Output frequency
Power factor
Switching at input
Mechanical data
Degree of protection
Class of protection
Cooling method
Sound pressure level
Protection against accidental
contact
Cabinet system
Paint finish
Compliance with standards
Standards
CE mark
RI suppression
Ambient conditions
Ambient temperature
Humidity range
(non-condensing)
Corresponds to class
Site altitude
Mechanical stability
Vibrational load
- Displacement
- Acceleration
Shock load:
- Acceleration
Applies to cable lengths of up to 100 m.
1)
476
47 Hz to 63 Hz
0 Hz to 300 Hz
Variable via reactive current (factory setting: cos ϕ = 1)
Once every 3 minutes
IP20 (higher degrees of protection up to IP54 optional)
To EN 50178, Part 1
Forced air cooling
≤ 78 dB(A) at 50 Hz line frequency
≤ 80 dB(A) at 60 Hz line frequency
BGV A 3
Rittal TS 8, doors with double-barb lock
RAL 7035 (indoor requirements)
EN 60 146-1, EN 61 800-2, EN 61 800-3, EN 50 178, EN 60 204-1, EN 60 529
To EMC directive No. 89/336/EC and low voltage directive No. 73/23/EC
In accordance with EMC product standard for variable-speed drives EN 61 800-3,
category C3 (category C2 on request)
Operation
0°C to +40°C
up to + 50°C with derating
5% to 95%
3K3 to IEC 60 721-3-3
Up to 2000 m above sea level without derating,
> 2000 m above sea level with derating (see "Derating data")
0.075 mm at 10 Hz to 58 Hz
9.8 m/s² at > 58 Hz to 200
Hz
100 m/s² at 11 ms
1)
Storage
-25°C to +55°C
5% to 95%
1K4 to IEC 60 721-3-1
1.5 mm at 5 Hz to 9 Hz
5 m/s² at > 9 Hz to 200 Hz
40 m/s² at 22 ms
Operating Instructions, 07/07, A5E00288214A
Transport
-25°C to +70°C
as of –40°C for 24 hours
5% to 95% at 40°C
2K3 to IEC 60 721-3-2
3.1 mm at 5 Hz to 9 Hz
10 m/s² at > 9 Hz to 200 Hz
100 m/s² at 11 ms
Drive converter cabinet units

Advertisement

Table of Contents
loading