Parameter settings
Table 4-40
Parameter
p0400[0]
p0404[0]
p0404[0].0
p0404[0].1
p0404[0].2
p0404[0].3
p0404[0].4
p0404[0].5
p0404[0].6
p0404[0].8
p0404[0].9
p0404[0].12
p0404[0].13
p0404[0].14
p0404[0].15
p0404[0].16
p0404[0].20
p0404[0].21
p0404[0].22
p0404[0].23
p0405[0]
p0408[0]
Drive converter cabinet units
Operating Instructions, 07/07, A5E00288214A
Parameter settings for 8-pole resolver on SMC10
Name
Enc type selection
Encoder configuration effective
Linear encoder
Absolute encoders
Multiturn encoder
Track A/B square-wave
Track A/B sinusoidal
Track C/D
Hall sensor
EnDat encoder
SSI encoder
Equidistant zero mark
Irregular zero mark
Distance-coded zero mark
Commutation with zero mark
Acceleration
Voltage level 5 V
Voltage level 24 V
Remote sense (only SMC30)
Resolver excit.
Square-wave signal encoder A/B track
Rotary encoder pulse No.
Electrical installation
4.9 Other connections
Value
Resolver 4 speed (1004)
800010(hex)
No
No
No
No
Yes
No
No
No
No
No
No
No
No
No
No
No
No
Yes
0(hex)
4
95