Racelogic VBOX Touch V2 User Manual page 54

Hide thumbs Also See for VBOX Touch V2:
Table of Contents

Advertisement

The screen is split in two halves:
• Left hand side:
◦ Lap time: This will show either a live rolling lap time, or a static previous lap time, dependent on the Rolling
Lap Time settings. If a rolling lap time is being displayed, the previous lap time will be displayed for 5 seconds
when a new lap starts before reverting to displaying the current live lap time. If the start/finish line has yet to be
crossed, the circuit name/layout will be displayed with a distance countdown to the start/finish line if the unit
has a satellite lock. If Standing Start has been enabled, a 'Standing Start Mode Enabled' message is
displayed. If no start/finish line been detected/defined, a 'No start line' warning will display.
◦ Time difference to best lap: This is the time difference between the last completed lap time and the quickest
lap time and is displayed dependent on the Rolling Lap Time settings. It will either display continuously if a
static lap time is being displayed, or will appear for 5 seconds after a lap has been completed if a rolling lap
time is being shown. If the start/finish line has yet to be crossed or a lap hasn't been completed, it will not be
shown.
◦ Reference lap time: Displays the current active reference lap time and will update when the reference lap is
superseded by a faster lap-time, unless the Reference Lap is Fixed within the Settings. If a reference lap has
been fixed, a padlock icon will show to the right of the reference lap heading. If a reference lap is being created,
a rolling lap time will show.
• Right hand side:
◦ Delta-T: Presents a live difference in lap time between the current lap time and the stored and active reference
lap at the current location on track. If the detected speed drops below 10 km/h or the satellite reception is lost
(less than 4 sats), the time comparison will freeze on the last known valid value until the speed is increased or
the satellite reception is regained. If a reference lap is being created, a 'Creating a Reference Lap' message is
displayed.
▪ If the current lap is faster than the reference lap, the value will be signed negative and
▪ If the current lap is slower than the reference lap, the value will be signed positive and
▪ If the current lap is the same as the reference lap, the value will be unsigned and black in colour.
◦ Session time: Total time passed within the session.
◦ Completed lap count: Number of completed laps within the session.
Delta-V:
When there is a stored and active reference lap, the 4 LEDs at the top of the screen will provide a live reference lap
speed comparison at the current location on track in relation to the Delta-V Range settings.
• If the current lap is faster than the reference lap, the LEDs will be
• If the current lap is slower than the reference lap, the LEDs will be
• If the current lap is the same speed as the reference lap, the LEDs will be off.
The main lap timing screen can be reset by pressing the Reset button at the bottom of the screen or by pressing and
holding on the screen.
User_Guide_%E2%80%93_VBOX_Touch_V2/05_Display_Modes_%E2%80%93_VBOX_Touch_V2/VBOX_Touch_V2_-
https://en.racelogic.support//Product_Info/VBOX_Data_Loggers/VBOX_Touch/VBOX_Touch_V2/
green
in colour.
red
in colour.
green
in colour.
red
in colour.
_Lap_Timing_Mode
54

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VBOX Touch V2 and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Vbtouch-v2

Table of Contents