Magic Scan Procedure - ICP DAS USA I-8014W User Manual

250 ks/s, 16-bit, 8-channel differential/16-channel single-ended analog input module
Table of Contents

Advertisement

Magic Scan Procedure

The program procedure is illustrated as below:
Initialize the module
Configure Magic Scan parameters
- Scan channel order (16 channels max.)
- Input range per channel
- Total sampling count
- Sampling rate (2~ 250 kHz)
- Scan mode
1 = standard mode
2 = virtual sample and hold mode
- Trigger method
0 = software trigger
1 = internal hardware trigger
2 = external hardware trigger
- External hardware trigger condition
0 = rising edge trigger
1 = falling edge trigger
Start Magic Scan
Read data from FIFO
till all data is obtained.
Stop Magic Scan
I-8014W API User Manual, v1.0.1, June 2011
Copyright © 2011 ICP DAS Co., Ltd. All Rights Reserved. E-mail: service@icpdas.com
Convert hexadecimal data to floating
point
Physical data