2. Firmware Update Procedure

NOTE: DS-700 using the same MiniOS7 and firmware with the PDS-700, and also provides virtual COM features.
The DS-700 is non-programmable serial-to-Ethernet devices server while the PDS-700 is programmable.
Step 1: Download the Firmware File of DS-700 module and then decompress it to a temp folder,
for example DS700fw.
Download the PDS-700 Firmware File.
The DS-700 firmware and autoexec.bat files are compressed in Zip format. You can decompress the zip file by
7-Zip, WinZip, WinRAR... utilities.
Step 2: Modify COM Port number in
to DS-700.
For Example (first parameter of the line 1 in the 7188xw.ini)
COM1 ==> C1 B115200 P0 D8 S1
COM2 ==> C2 B115200 P0 D8 S1
Double Click
1
Firmware Update via 7188XW.exe (Ver. 1.0/Aug. 2018)
7188xw.ini
file, depend on your PC COM Port that connect
Select the "Save" item from the "File"
menu to save the new configuration.
2
C: COM Port (e.g. C7)  Modify this item.
B: Baud Rate (e.g. B115200)
P: Parity (e.g. P0)
D: Data Bits (e.g. D8)
S: Stop Bits (e.ge. S1)
3
Page: 3