ICP DAS USA I-8014W User Manual page 52

250 ks/s, 16-bit, 8-channel differential/16-channel single-ended analog input module
Table of Contents

Advertisement

If the system uses Windows platform, converting hexadecimal data to floating point
data would not affect the CPU load. You can convert data local and then transfer the
floating data through Ethernet.
Tips & Warnings
It is recommended to create several buffers to deal with the data
obtained from FIFO and reuse them in process as the figure below.
This allows the system has time to convert data, save and transfer
them.
Buffer 0
2000 samples of
data collected
T0
I-8014W API User Manual, v1.0.1, June 2011
Copyright © 2011 ICP DAS Co., Ltd. All Rights Reserved. E-mail: service@icpdas.com
Buffer 1
2000 samples of
data collected
Buffer 0
T1
Transferring data
through Ethernet
Buffer 2
2000 samples of
data collected
Buffer 1
T2
Transferring data
through Ethernet
Time
axis