E-Rds Setting Items; Steps To E-Rds Settings - Canon imageRUNNER 1750 Series Service Manual

Hide thumbs Also See for imageRUNNER 1750 Series:
Table of Contents

Advertisement

2
Technical Explanation > Embedded RDS > E-RDS Setup > Steps to E-RDS settings

■ E-RDS setting items

Item
#E-RDS >
Disable/Enable of Embedded-RDS function
E-RDS SWITCH
0: Disable/ 1:Enable
e-Maintenance/ imageWARE Remote system to send device information,
counter data, error statuses to the UGW.
Default : 0 (not in use)
#E-RDS >
URL of UGW
RGW-ADDRESS
Default : https://a01.ugwdevice.net/ugw/agentif010
#E-RDS >
Set port number of UGW
RGW-PORT
Validation : 1 to 65,535
Default : 443
#E-RDS >
Execution of a communication test with UGW / Display of the result
COM-TEST
Perform Communication test with UGW and set "OK" or "NG" as the
result.
#E-RDS >
Display of detailed information about a communication error with UGW
COM-LOG
Error information of a connection failure with UGW is displayed.
Error occurrence date and time, error code, and detailed error information
are displayed.
Max 5 latest loggings retained
Max 128 characters for Error information.
#CLEAR >
Initialization of E-RDS SRAM data
ERDS-DAT
SRAM data of E-RDS is initialized and returned to the factory setting
value at shipment.
#CLEAR >
Initialization of CA certificate
CA-KEY
When the power is turned OFF/ ON after execution, the CA certificate in
the factory setting is automatically installed.
#REPORT >
COM-LOG Report
REPORT OUTPUT >
The report output of the communication error logging information on five
ERDS COM LOG LIST
affairs can be carried out.
2
Technical Explanation > Embedded RDS > E-RDS Setup > Steps to E-RDS settings
Description
T-2-54

■ Steps to E-RDS settings

1. Start [Service Mode].
1) Press [Additional Functions (User Mode)] button on the control panel.
2) Press [2] buttons on the control panel.
3) Press [8] buttons on the control panel.
4) Press [Additional Functions (User Mode)] button on the control panel.
The example of the service mode indication screen
OK Key
#E-RDS
E-RDS SWITCH
Key
OK Key
#E-RDS
RGW-ADDRESS
Key
OK Key
#E-RDS
RGW-PORT
Key
OK Key
#E-RDS
COM-TEST
Key
OK Key
#E-RDS
COM-LOG
Key
OK Key
#E-RDS
SCALLCMP
2-80
F-2-118
#E-RDS
001
1
#RGW-ADDRESS
:A
https://a01.ugwdevi..
#RGW-PORT
001
443
#E-RDS
COM-TEST OK
No:1 Ecode:870F2052
2011 03/24 11:56
#SCALLCMP
OK
F-2-119
2-80

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Imagerunner 1740 seriesImagerunner 1730 series

Table of Contents