Canon imageRUNNER 1750 Series Service Manual page 212

Hide thumbs Also See for imageRUNNER 1750 Series:
Table of Contents

Advertisement

5
Adjustment > Overview > Image Position Adjustment
Overview
Adjustment when replacing parts
This section describes adjustment required in field service works when replacing parts.
The parts are classified by function into the following 3 blocks.
Category
Replacing parts
Original
Replacement parts
Exposure
Contact Image Sensor (CIS)
Copyboard Glass
System
Reading Glass
Controller
Main Controller PCB
System
DC Controller PCB
RAM PCB
Laser Exposure
Laser Scanner Unit
System
Image Position Adjustment
This section describes remedies when adjusting the basic image position.
Item
Specification value
Left Edge Margin
1-sided: 2.5 +/- 1.5 (mm)
Adjustment
2-sided: 2.5 +/- 2.0 (mm)
2.5+/-1.5mm
(2nd side of double-sided copy:
2.5+/-2.0mm)
0
2
4
5
6
8
10
5
Adjustment > Overview > Image Position Adjustment
Reference
Refer to page 5-3
Refer to page 5-3
Refer to page 5-4
Refer to page 5-4
Refer to page 5-5
Refer to page 5-5
Refer to page 5-5
T-5-1
Reference
Refer to page 5-6
F-5-1
Item
Specification value
Leading Edge
1-sided: 2.5 +/- 1.5 (mm)
Non-image Width
2-sided: 2.5 +/- 1.5 (mm)
Adjustment
(2nd side of double-sided copy
0
2
4 6 8 10 12 14 16 18 20
5
Left Edge Non-
1-sided: 2.5 +/- 1.5 (mm)
image Width
2-sided: 2.5 +/- 1.5 (mm)
Adjustment
2.5+/-1.5mm
(2nd side of double-sided copy:
2.5+/-1.5mm)
0
2
4
5
6
8
10
Reference
Refer to page 5-6
2.5+/-1.5mm
: 2.5+/-1.5mm)
F-5-2
Refer to page 5-7
F-5-3
5-2
T-5-2
5-2