Disassembly/Assembly > Original Exposure/Feed System > Removing the Reader Unit > Procedure
2) Pass the Flat Cable [1] through the hole [A] of the plate and downward.
3) Remove the 2 Screws [2].
[1]
x2
4) Remove the Reader Right Front Fixation Plate [1] and the Reader Right Rear Fixation Plate
[2].
• 4 Screws [3]
x4
4
Disassembly/Assembly > Original Exposure/Feed System > Removing the Reader Unit > Procedure
[A]
[2]
F-4-72
[1]
[2]
[3]
[3]
F-4-73
5) Remove the Reader Unit [1].
• 4 Screws [2]
x4
[2]
4-45
[1]
F-4-74