3. Remove the cartridges from the I/O Station to access the screw located on the
4. Remove the screw located on the backside of the I/O Station door.
5. Hold the I/O Station slide assembly in place with one hand and, using your
6. Set aside the old front bezel.
Replacing the I/O Station Bezel
To replace the I/O Station bezel, perform the remove procedures in reverse order.
For the last step, perform "Returning a Library or Library Module to Normal
Operations after Repairs" on page 8-4.
Removing the Access Door Bezel
1. Perform "Preparing a Library or Library Module for Repairs" on page 8-4.
2. Open the module's I/O Station and Access Doors.
3. Remove the screws located on the backside of the Access Door.
Figure 8-24. Control module Access Door screw locations
backside of the I/O Station door.
other hand, pull the I/O Station door directly up to disengage the bolts, and
then pull the door toward you.
Note: When you open the Access Door, the library becomes disabled (the
Picker assembly does not function). When you later close the Access
Door, the library will function normally.
v For the control module (11 screws), see 1 in Figure 8-24.
1
1
v For an expansion module (12 screws, see 1 in Figure 8-25 on page 8-28.
Chapter 8. Add, Check, Adjust, Remove, and Replace Procedures
1
1
8-27