Original Picker Assembly; Y-Axis/Picker Assembly - IBM TS3310 Maintenance Information

System storage tape library
Hide thumbs Also See for TS3310:
Table of Contents

Advertisement

Figure 8-59. Y-axis/Picker Assembly rollers inserted in gear rack track
10. If necessary, perform one of the following procedures:
11. Perform "Returning a Library or Library Module to Normal Operations after

Original Picker Assembly

The Picker moves media to and from storage slots and tape drives and positions
the Bar Code Scanner to enable it to read bar code labels on cartridges and
fiducials on cartridge magazines and tape drives. The Picker Assembly can be
removed through the top of the library (recommended method) or through an
Access Door opening in the library.
Removing the Picker Assembly from the Y-axis Assembly in a
Stand-alone Library
1. If necessary, vary all drives offline, then power OFF the library.
2. Remove the top cover of the library.
3. Open the I/O Station door then the Access Door to access the Y-axis/Picker
4. Optionally, remove the I/O Station from the expansion unit for easier access.
5. Facing the library, rotate the Picker Assembly until the front of the Picker
7. Replace the I/O Station (see "Reinstalling an I/O Station" on page 8-36).
8. Close the Access Door then the I/O Station door.
9. Replace the top cover of the control module, if necessary.
v "Replacing a 5U Library (Control Module) in a Rack" on page 8-5
v "Replacing a Control Module in a Standalone or Rack-mounted Library
(14U or larger)" on page 8-12
Repairs" on page 8-4.
Assembly.
See "Removing an I/O Station" on page 8-35.
Assembly is oriented approximately 45 degrees right of center, as seen from the
top of the library, to access the flat cable connector ( 1 in Figure 8-60 on page
8-60).
1
Chapter 8. Add, Check, Adjust, Remove, and Replace Procedures
2
8-59

Hide quick links:

Advertisement

Table of Contents
loading