Operating Limits

Input Voltage

The allowable Freedom EX 4000 input battery voltage ranges are
shown in the following table:
Table 6 Input battery voltage range
Operating
Battery Voltage
Condition
Full
LBCO – 64.0
Operating
volts
Range
Low
> LBCO +
Voltage
LBCO Hysteresis
c
Recovery
volts
a
 To set LBCO, see Adjusting Settings in Configuration Mode on page 31.
b
 To set LBCO Shutdown Delay Timer, see Input Voltage on page 24.
c
 6.0 volts is the default LBCO Hysteresis value. The range is from 0.0 to 10.0 volts.
24
Comment
Assuming the battery is full,
the inverter/charger/converter
will operate until battery
voltage goes past below
a
LBCO
and LBCO Shutdown
b
delay timer
.
Inverter is able to recover and
continue to operate.
Operating
Battery Voltage
Condition
Low
Voltage
< LBCO
Shutdown
Instant
Low
< 32.0 volts
Voltage
Shutdown
Comment
If installed, the display on the
Freedom EX Remote Panel
(PN: 808-0817-03) shows
error code E01 and the buzzer
sounds a single one-second
low battery alarm beep.
After LBCO Shutdown delay
timer runs out, the unit shuts
down inverter output. The
buzzer stops beeping and the
display on the Freedom EX
Remote Panel (PN: 808-0817-
03) shows error code E01.
After two seconds below the
limit, the unit shuts down
inverter output completely.