Adjusting Settings in Configuration Mode
Setting
Setting Name
Number
I4
Search Threshold
I5
Search Delay
I6
Power Save
38
Default
Range of Values
Value
50
25 to 255
2
1 to 25
DIS
EnA (enable)
(disable)
DIS (disable)
Unit Step
W
5
Sets the inverter's search sensitivity when
Search mode is enabled. When a load larger
than this setting is present, the inverter turns on.
s
1
Sets the time between search pulses. When
searching for loads, the Freedom EX 4000
sends out search pulses to determine if a load
is present. If the Freedom EX 4000 finds a load
above the Search Threshold setting, the inverter
turns on.
--
--
Enables or disables Power save mode. When
enabled, the Freedom EX 4000 reduces tare
loss from the battery by reducing the inverter
output from 120 volts to 108 volts when the
loads consume less than 100 watts.
Description
Freedom EX 4000 Owner's Guide