Xantrex Freedom EX 4000 Owner's Manual page 77

Inverter/charger with 48vdc-to-12vdc converter
Hide thumbs Also See for Freedom EX 4000:
Table of Contents

Advertisement

   Shore to inverter:
   Inverter to shore:
Waveform
Peak Efficiency
Idle consumption
(DC-DC converter has no load. Remote
display, RV-C control, and BTS are
connected.)
Cooling
975-0999-01-01
Freedom EX 4000
Shore voltage greater
than 125V(min) - 138V
(default) - 144V(max)
Shore voltage less than
above value – 2V
hysteresis
True Sine Wave
95.5 %
< 0.3 W
(Power button on
unit is Off (Standby))
< 8 W
(Power button on unit is
On, inverter mode disabled,
charger mode enabled)
< 30 W
(Power button on unit
is On, inverter and charger
mode enabled)
Fan, activated by any of
the following:
High internal
n
temperature
High AC output
n
power
Table 11 DC input for inverting
Nominal voltage
Operating voltage
Maximum current at full load
Table 12 DC output for charging
Nominal voltage
Maximum voltage
Maximum charge rate
Power factor corrected charging
b
 Contact Xantrex prior to stacking two Freedom EX 4000 units together. Stacking configuration via USB is
a required step to enable stacking.
Environmental Specifications
Freedom EX 4000
48 VDC
40–64 VDC
130 ADC
Freedom EX 4000
48 VDC
64 VDC
80 A single unit
160 A when parallel or
b
series stacked
PF (0.98)
61

Advertisement

Table of Contents
loading

This manual is also suitable for:

820-4080-4

Table of Contents