Environmental Specifications

Environmental Specifications
Table 9 Environmental specifications
Rated Temperature Range
Operating Temperature Range
Storage Temperature Range
Humidity: Operation/Storage
Ingress Protection Rating
a
Operation may be limited based on the battery chemistry. For example, Lithium Iron Phosphate batteries
have a limited charging temperature range. Follow specific battery manufacturer recommendations for the
applicable chemistry.
60
Freedom EX 4000
0–40 °C (32 –104 ºF)
a
-10 –60 ºC (14 –140 ºF),
with output derated above
40 °C (104 ºF)
-40 –70 ºC (-40 –158 ºF)
5–95% RH, non-
condensing
IP20

System Specifications

Table 10 System specifications
a
Transfer relay rating (A
)
Transfer time (milliseconds)
   Shore to inverter:
   Inverter to shore:
Transfer voltage (V)
   Shore to inverter:
   Inverter to shore:
a
Circuit breakers shall not carry more than 80% of their UL current rating continuously.
Freedom EX 4000
40A (continuous)
50A (max)
<10 milliseconds
<10 milliseconds with a
20-second delay
Shore voltage less than
60V(min) - 80V(default) -
115V (max)
Shore voltage greater
than above value + 2V
hysteresis