AC Input Specifications
AC input voltage range
Maximum AC input current
Power factor at rated load
Frequency
Efficiency – peak
Surge protection
975-0402-01-01
This guide for use by qualified installers only
Nominal: 120 Vac, 230 Vac, 240 Vac
Full Performance: 105 – 265 Vac ±4 Vac
Automatic derating to 80%: 90 – 104
±4 Vac
at 104 Vac
TC1012: 2.5 A
TC1512: 3.5 A
TC2012: 4.5 A
TC3012: 7.0 A
TC4012: 9.0 A
TC5012: 11.5 A TC5012: 5.5 A
TC6012: 13.5 A TC6012: 6.5 A
TC1524:
7.0 A
TC2024:
9.0 A
TC3024:
13.5 A TC3024: 7.0 A
TC5024:
22.5 A TC5024: 11.5 A
≥0.95
47 – 63 Hz
12 V units: 77% @ 120 Vac, 80% @
230 Vac
24 V units: 85% @ 120 Vac, 87% @
230 Vac
Line-to-neutral surge protector rated at 275
Vac
AC Input Specifications
at 208 Vac
TC1012: 1.5 A
TC1512: 2.0 A
TC2012: 2.5 A
TC3012: 3.5 A
TC4012: 4.5 A
TC1524: 3.5 A
TC2024: 4.5 A
A–5