BATTERY OPERATION

Please read this section for safety information and operational
instructions regarding your XPLORE Charger. This section
includes:
975-1038-01-01
Input Voltage Operating and
Derating
When AC input is within the lower range between 90-108 VAC,
31
the XPLORE Charger derates to 80% of maximum current.
31
However, when AC input increases above 108 VAC up to
32
265 VAC, maximum current returns to 100% capacity.
33
Furthermore, the XPLORE Charger will continue to operate at
100% of maximum current.
33
34

Dual Chemistry Charging

34
34
The XPLORE Charger allows either Group 1 or Group 2 to charge
batteries of a different chemistry. The outputs share the full rated
current enabling it to charge two different battery kinds and can
tolerate the same charge sequence and thresholds.
NOTE: The battery banks are not galvanically isolated from each
other. They share a common negative as shown in Figure 14 .
The negative bus to DC neg(-) bus connection as shown below
may not be suitable in some applications.