Input Voltage Operating and Derating

When there is an AC input out of range warning in the lower
range between 90–108 Vac, the Truecharge™ 2 Battery
Charger derates to 80% of maximum current.
However, when AC input increases above 108 Vac up to
255 Vac, maximum current returns to 100% capacity.
Furthermore, the Truecharge™ 2 Battery Charger will
continue to operate at 100% of maximum current, even while
there is an AC input out of range warning in the upper range
between 256–265 Vac.

Battery and Charger Temperature Thresholds

FAULT set
FAULT reset
-25
-20
-15
COLD (default 0 °C)
-25 -20 -15 -10 -5
Figure 1-5 Battery and Charger Temperature Thresholds
975-0401-01-01
ALARM set
ALARM reset
-10
-5
0
+5
0
5
10
15
Ambient Temperature
Onboard Control and Status Display Panel
+10
+20
+30
WARM (default 25 °C)
Charger
ALARM reset
20
25
30
35
40
ALARM set
ALARM reset
FAULT reset
+40
+50
+60
HOT (default 35 °C)
Charger
ALARM set
Charger
FAULT reset
45
50
55
60
65 70 °C
derating to
80% Imax.
FAULT set
+70 °C
Charger
FAULT set